Double flange transmitter is widely used in industrial automation control system, and its inspection and maintenance are very important to the stable operation of the system. When using a double-flange transmitter, you need to pay attention to the following aspects:
regularly check whether the appearance of the transmitter is in good condition. If there is obvious damage or corrosion, it should be stopped immediately and repaired. At the same time, check the sealing performance of the transmitter to ensure that its working environment meets the requirements.
check the electrical connection of the transmitter to ensure that the connection is firm and reliable, and avoid problems such as poor contact or short circuit. For occasions with explosion-proof requirements, it is also necessary to check whether the explosion-proof grounding meets the requirements to ensure safety.
periodically calibrate the output signal of the transmitter to ensure its measurement accuracy and stability. Before calibration, the transmitter should be cleaned and maintained to eliminate factors that may affect the measurement, such as dust accumulation or liquid spills.
In addition, the sensor and measuring elements of the transmitter are cleaned regularly to ensure its sensitivity and accuracy. At the same time, pay attention to avoid the use of chemical solvents and other damage to the transmitter, select the appropriate cleaning methods and tools for maintenance.
regularly conduct performance tests on the transmitter, such as zero drift test, linearity test, etc., to ensure that its measurement performance meets the requirements. In case of abnormality, fault analysis and treatment shall be carried out in time to ensure that the transmitter can work normally.
In general, the inspection precautions of double flange transmitters involve appearance, sealing, electrical connection, calibration, cleaning, and performance testing, which need to be taken seriously. Only regular and strict inspection and maintenance can ensure the normal operation of the double flange transmitter and effectively deal with various challenges that may be encountered in the work.
Cyclical fluctuations in the chemical industry, when will the next boom cycle come?
Jihua 240000 Tons Bisphenol A Plant Successfully Completed Mechanical Completion, Industry Shuffle Accelerated?
The total budget is 2.328 billion yuan, and the 100000-ton BDO and 120000-ton PBAT projects in Anhui have been successfully fed.
Nanjing Jiangbei pilot base started! Nanjing Chengzhi MMA pilot project settled in!
With a total investment of 1.024 billion yuan, 240000 tons/year of polyether is diversified and delivered smoothly.
Longnan Xintao Project Expansion EIA Publicity, New 20000 Tons of PMMA Capacity
Quick Response
Customer service is available 24/7 for extremely fast response
Exclusive Services
Dedicated consultant 1 to 1 service
Massive Resources
Connecting resources upstream and downstream
Technology Advanced
Technology Information Service
Transaction Security
Merchant authentication and risk control model
One-stop service
Trading logistics warehouse-style services